TI中文支持网
TI专业的中文技术问题搜集分享网站

XDS给CC1310烧写出现问题

多次尝试烧写没有成功,TEXT CONNECTION 如下

[Start: Texas Instruments XDS100v3 USB Debug Probe]

Execute the command:

%ccs_base%/common/uscif/dbgjtag -f %boarddatafile% -rv -o -F inform,logfile=yes -S pathlength -S integrity

[Result]

—–[Print the board config pathname(s)]————————————

C:\Users\ADMINI~1\AppData\Local\TEXASI~1\
CCS\CCS611~1.000\0\0\BrdDat\testBoard.dat

—–[Print the reset-command software log-file]—————————–

This utility has selected a 100- or 510-class product.
This utility will load the adapter 'jioserdesusbv3.dll'.
The library build date was 'Sep 4 2015'.
The library build time was '21:59:23'.
The library package version is '6.0.14.5'.
The library component version is '35.35.0.0'.
The controller does not use a programmable FPGA.
The controller has a version number of '4' (0x00000004).
The controller has an insertion length of '0' (0x00000000).
This utility will attempt to reset the controller.
This utility has successfully reset the controller.

—–[Print the reset-command hardware log-file]—————————–

The scan-path will be reset by toggling the JTAG TRST signal.
The controller is the FTDI FT2232 with USB interface.
The link from controller to target is direct (without cable).
The software is configured for FTDI FT2232 features.
The controller cannot monitor the value on the EMU[0] pin.
The controller cannot monitor the value on the EMU[1] pin.
The controller cannot control the timing on output pins.
The controller cannot control the timing on input pins.
The scan-path link-delay has been set to exactly '0' (0x0000).

An error occurred while hard opening the controller.

—–[An error has occurred and this utility has aborted]——————–

This error is generated by TI's USCIF driver or utilities.

The value is '-230' (0xffffff1a).
The title is 'SC_ERR_PATH_MEASURE'.

The explanation is:
The measured lengths of the JTAG IR and DR scan-paths are invalid.
This indicates that an error exists in the link-delay or scan-path.

[End: Texas Instruments XDS100v3 USB Debug Probe]

各位工程师,你们好,我今天刚刚买来XDS100V3,在烧写的过程中报错,如下(我用的是CCS6)

但是我 的SmartRF可以识别

接线图如下,下面两对电源5V是外接的,3.3V是接的仿真器的,想问一下这个3.3V是给芯片的供电吗,还有上面的错误是什么原因呢

Susan Yang:

请问您在CCS中connection选项是否选择Texas Instrunments XDS100V3 USB Debug Probe?