DLPA3000 Thermal Pad

as DLPA3000 spec & SLMA002 define:

1. Thermal pad:12.00×12.00;

2. Exposed thermal pad:6.00×6.00;

3. VIA 7×7;

Detail footprint as attachment;

But to my opinion, exposed thermal pad 12.00×12.00 has good thermal dissipation than 6.0×6.0;

The reason for TI suggestion to Choosing exposed thermal pad 6.0×6.0 is ….??

MengAo Zeng:

The 12mm x 12 mm is not the thermal pad dimensions.  It is the distance between the first and last pin on the side of the die.  The first drawing is a generic drawing for all HTQFP devices, and it has a note that says to refer to the datasheet for the pad dimensions.  The pad dimensions are specified in the second drawing, which is the specific drawing for our package. 

HZ_Xu:

回复 MengAo Zeng:

dear sir,

Thanks for your request. 

SLMA002 says vias is good to thermal.

Adding  vias for DLPA3000 footprint is better??

MengAo Zeng:

回复 HZ_Xu:

Yes. The vias will be helpful to thermal design. Thanks.

HZ_Xu:

回复 MengAo Zeng:

dear sir,

PICO Projector based on DLPA3438 & DLPA3000,

if DLPA3000 analog sensor signal pins are not used, left them floating or ………….??

I can't find it in data sheet;

MengAo Zeng:

回复 HZ_Xu:

If you didn't connect light sensor or temperature sensor with DLPA3000, the sensor related pins can be left open or unconnected. Please find more details on DLPA3000 datasheet (Page37).

Bill Chen:

回复 MengAo Zeng:

dear sir,

according to DLPA3005 design sch–2514006_20141230,as image shows, adds two diodes for PWR1,2,5,6,7;

Need to add diodes for DLPA3000??

MengAo Zeng:

回复 Bill Chen:

No need diodes for DLPA3000 PWR1/2/5/6/7 converters. But PWR5/6/7 should not be used currently. Please refer to DLPA3000 datasheet for details.

HZ_Xu:

回复 MengAo Zeng:

1. No need diodes for DLPA3000 PWR1/2/5/6/7 converters.

==>if possible, May I know the reason for diodes for DLPA3005??

2. But PWR5/6/7 should not be used currently.

==>what does this means?? software is not ready to control this??

3. if one of PWR1,2,5,6,7  powers is not used, may NC parts for cost down??

==>

MengAo Zeng:

回复 HZ_Xu:

Yes. The PWR5/6/7 pins of DLPA3000 can be left open/unconnected.

Bill Chen:

回复 MengAo Zeng:

DLPA3000 data sheet Page 9  shows:

Typical Application: 6 A LED, Internal FETs,

DMD type TRP.

ACTIVE mode, all VIN pins combined, DMD, ILLUMINATION and PWR1,2 enabled, PWR3,4,5,6,7 disabled.

 

==>if this means, only PWR1,2 can be used while using DMD Type TRP??

 