TI中文支持网
TI专业的中文技术问题搜集分享网站

BQ40Z50: How to close "Hardware protection" detect by bq40Z50

Part Number:BQ40Z50

How to close "Hardware-Based Protection" detect? 

Now we always trigger AOLD protection.

Because our new product "Peak Current" has a high chance to over  -100A 

Cherry Zhou:

Hi,

We've got the issue and look the help from our experts, please expect the response.

Thanks

,

Cherry Zhou:

Hi,

100mV is the max the gauge can be set to for this protection, you would have to use a lower sense resistor in order to support applications with over 100A discharges.

Thanks

,

Tin Chang:

Hi Cherry,

Thanks a lot.

I understand. We will change a lower sense resistor to close the issue.

But..Why can the maximum value of ASCDx reach -200mV?

,

Cherry Zhou:

Please give us some time to get back to you.