Part Number:IWR6843ISKOther Parts Discussed in Thread: MMWAVEICBOOST

我尝试运行mmwave_industrial_toolbox_4_8_0\labs\traffic_monitoring\18xx_68xx_traffic_monitoring的这个例程,按照使用说明的步骤进行操作。当运行GUI程序tm_visualizer.m的时候,提示端口能打开但是无法回复信息,请问如何解决呢?(板子的SOP都是照着教程做的,应该没问题)下面的代码是允许tm_visualizer.m时的输出

Opening tm_demo_uart_stream.txt. Ready to log data. 
Opening configuration file 
Parsing configuration file...
Skip parsing for: sensorStop command
Skip parsing for: flushCfg command
Error: number of parameters is incorrect for stateParam commandError: number of parameters is incorrect for trackingCfg commandSkip parsing for: sensorPosition command
Skip parsing for: presenceBoundaryBox command
Skip parsing for: sensorStart command
COM4 opened. 
COM3 opened. 
Port opened but no response received. Check port # and SOP mode on EVM>> 

Shine:

请问traffic_monitoring_68xx_demo.bin正确烧写了么?

请点击一下test connection看串口是否能连接?

,

Wreng Song:

traffic_monitoring_68xx_demo.bin可以烧写。点击test connection就弹出上图中的窗口 Port opened but no response received

,

Shine:

修改SOP配置后,有没有reset一下或者板子重新上电?另外,IWR6843ISK是ES2.0硅版本么?

,

Wreng Song:

有reset。

IWR6843ISK是ES2.0的

,

Shine:

看不出芯片表面打印,可以参考下面的勘误表上的表面打印,看一下是不是 678A?https://www.ti.com/lit/er/swrz087c/swrz087c.pdf板子的开关配置是正确的,请看一下电源是否是5V, 3A 以上? 如果还是不行,请尝试直接双击tm_visualizer.exe,换个串口,或者换台电脑。

,

Wreng Song:

芯片表面确实是678A。

单独使用的IWR6843ISK天线模块可以正常运行,但是加上MMWAVEICBOOST就不行了,还是报同样的错误。此例程对MMWAVEICBOOST板子有什么设置要求吗(里面的跳线不知道接对没有)?

,

Shine:

看您的图是接对了,您再按照下面的网站核对一下。https://dev.ti.com/tirex/explore/content/mmwave_industrial_toolbox_4_8_0/labs/common/docs/hardware_setup/hw_setup_mmwaveicboost_mode_functional.html

赞(0)