cc1310 jtag xds100v3 不能找到设备

工程师你好:

使用CCS10.1.1,自制的CC1310板子(参考launchXL-cc1310),通过XDS100V3连JTAG;

在CCS及SmartRF flash programmer中可以看到XDS100V3,但不能看到CC1310,不能进行仿真及下载,在ccxml中进行test Connection如下:

[Start: Texas Instruments XDS100v3 USB Debug Probe_0]

Execute the command:

%ccs_base%/common/uscif/dbgjtag -f %boarddatafile% -rv -o -F inform,logfile=yes -S pathlength -S integrity

[Result]

—–[Print the board config pathname(s)]————————————

C:\Users\nila1\AppData\Local\TEXASI~1\CCS\
ccs1011\0\0\BrdDat\testBoard.dat

—–[Print the reset-command software log-file]—————————–

This utility has selected a 100- or 510-class product.
This utility will load the adapter 'jioserdesusbv3.dll'.
The library build date was 'May 7 2020'.
The library build time was '21:10:18'.
The library package version is '9.2.0.00002'.
The library component version is '35.35.0.0'.
The controller does not use a programmable FPGA.
The controller has a version number of '4' (0x00000004).
The controller has an insertion length of '0' (0x00000000).
This utility will attempt to reset the controller.
This utility has successfully reset the controller.

—–[Print the reset-command hardware log-file]—————————–

The scan-path will be reset by toggling the JTAG TRST signal.
The controller is the FTDI FT2232 with USB interface.
The link from controller to target is direct (without cable).
The software is configured for FTDI FT2232 features.
The controller cannot monitor the value on the EMU[0] pin.
The controller cannot monitor the value on the EMU[1] pin.
The controller cannot control the timing on output pins.
The controller cannot control the timing on input pins.
The scan-path link-delay has been set to exactly '0' (0x0000).

An error occurred while hard opening the controller.

—–[An error has occurred and this utility has aborted]——————–

This error is generated by TI's USCIF driver or utilities.

The value is '-275' (0xfffffeed).
The title is 'SC_ERR_SCAN_POLL_BUSY'.

The explanation is:
The attempt to poll a target device exceeded its timeout limit.
The utility or debugger has requested that a target device be
repeatedly accessed for a specific data or status value.
This has failed because the built-in limit for the maximum number
of attempts when polling the JTAG scan-path has been exceeded.

[End: Texas Instruments XDS100v3 USB Debug Probe_0]

[Start: UARTConnection_0]

Execute the command:

The Diagnostic Command is not defined in the connection properties.

直接进行debug则会有以下提示:

请问是什么原因呢?

Viki Shi:

自制板的话,原因比较多,建议先按照checklist排查一下硬件:
www.ti.com/…/swra640e.pdf

lin jqi:

回复 Viki Shi:

谢谢回复!

有个硬件现象请帮忙分析一下,以便确认硬件是否有问题:

在还没有烧录程序的时候,测试DCDC和晶振都没有波型,是否正常呢?

谢谢!

Viki Shi:

回复 lin jqi:

晶振不起振怎么烧录进去程序?