TI中文支持网
TI专业的中文技术问题搜集分享网站

PGA-400Q1-EVM下载程序返回读0或读0XFF,求解决,多谢。

硬件连接如图,四个LED均亮。上位机软件未进行任何设置,初始状态下进行HEX文件选取和下载,总会出现如下错误:

ERROR – OTP Progamming was NOT successful. Please check the 'Error' Tab for more information
ERROR – Register 026A, was programmed to: 22, but read back: 00
ERROR – Register 0269, was programmed to: EF, but read back: 00
ERROR – Register 0268, was programmed to: 80, but read back: 00
ERROR – Register 0267, was programmed to: A3, but read back: 00
ERROR – Register 0266, was programmed to: 0D, but read back: 00
ERROR – Register 0265, was programmed to: F5, but read back: 00
ERROR – Register 0264, was programmed to: 0D, but read back: 00
ERROR – Register 0263, was programmed to: 25, but read back: 00
ERROR – Register 0262, was programmed to: 93, but read back: 00

……

有时候读返回是0XFF,不知怎么回事,求各位大哥哥大姐姐知道。感谢。灰常感谢。期待很棒的你们的回答。

song zhao:

回复 Mister Lei:

老兄,非常感谢。。是啊。哎,刚毕业的小生才接触TI。。望原谅。

song zhao:

回复 song zhao:

量了下VDD电源怎么是7.5V、、、额  大哥 你有木有实时通讯工具 想向您请教下 我的企鹅 378591782 多谢

赞(0)
未经允许不得转载:TI中文支持网 » PGA-400Q1-EVM下载程序返回读0或读0XFF,求解决,多谢。
分享到: 更多 (0)