TI中文支持网
TI专业的中文技术问题搜集分享网站

C6747定时器的使用问题

在C6747的使用过程中想利用两个定时器,我选择的是Timer0的12和34,对应的配置如下:

void initExint(void)
{  CSR&=0xfffe;
 asm(" NOP 2 ");
 TIMER0_EMUMGT=0x1;     //the timer runs free regardless of the soft bit

 TIMER0_TGCR=0x317;      //采用32位独立定时器12与34
    TIMER0_TIM12=0;          //This 32-bit value is the current count of the main counter.
                                           //定时器12的起始值为0
 TIMER0_TIM34=0;          //This 32-bit value is the current count of the main counter.
                                            //定时器34的起始值为0
                                     
 TIMER0_PRD12=0x10a;      //This 32-bit value is the number of timer input clock cycles to count.
 TIMER0_PRD34=0x2710;     //600Hz的定时器计数单元
 
 TIMER0_INTCLSTAT=0x30003;    
 

 TIMER0_TRC=0x00800080;   //开定时器12/34,continuously,
 INTMUX1=0x044000;                          // 指定Timer0INT(为4号中断)到中断5(INT5),将Ex4INT指定到INT4 EX6INT到INT6
 ISTP=0x80000000;                    // 重置中断向量表到0C00h
 ICR=0xfff0; 
 ISR=0x0;                            // 清除等待的中断
 IER=0xffff;                      // 使能ADINT中断     }

程序运行过程中仅发现Timer0 12对应的变量值会改变,而Timer0 34对应的变量值不变,在34对应的中断服务子程序中设置断点也进不去,

请问我该如何解决这个问题?谢谢。

xiaoting hu:

你好,请问你提出的问题解决了吗?我也遇到跟你差不多的问题了,能不能说说问题出在哪里呢?

赞(0)