TI中文支持网
TI专业的中文技术问题搜集分享网站

请问CC2530 的核心功耗和频率的关系

CC2530可以通过时钟管理寄存器设置降频,我想问的是,手册上仅给出了主时钟为32M外置晶振时的核心工作功耗以及使用内置16MRC时的核心工作功耗,而没有给出设为更低频率时的核心工作功耗,譬如,我想知道设为1M或者2M时的核心功耗究竟是多少?

Peter_Zheng:

System clock-source select. Setting this bit initiates a clock-source change only.

CLKCONSTA.OSC reflects the current setting.

0: 32 MHz XOSC

1: 16 MHz RCOSC

只有2种系统时钟可选择。低功耗可以设置为mode3如图

Jane Yang:

CC2530不能工作在1m或者2m的频率下。

licheng Li:

回复 Jane Yang:

谢谢回复!但我还有疑问,如果只能用32M或者16M,那用户指南里的CLKCONCMD寄存器里提到的几种频率是什么应用场合下用的?

Peter_Zheng:

All timer functions are based on the main 8-bit counter found in Timer 3 and Timer 4. The counter

increments or decrements at each active clock edge. The period of the active clock edges, as defined by

the register bits CLKCONCMD.TICKSPD[2:0], is further multiplied (the frequency is divided) by the

prescaler value set by TxCTL.DIV[2:0] (where x refers to the timer number, 3 or 4). The counter

operates as either a free-running counter, a down counter, a modulo counter, or an up/down counter.

应该是timer的时钟源。不是系统时钟,系统主时钟只有16/32Mhz两种

WZ:

回复 Peter_Zheng:

主频可以分频,clkconcmd也可以通过降低系统时钟的方式来降低电流功耗。同样降低频率后外设的时钟源也会降低。抱歉目前没有官方的频率和电流的表格。

赞(0)
未经允许不得转载:TI中文支持网 » 请问CC2530 的核心功耗和频率的关系
分享到: 更多 (0)