有多个问题要问:
1.官方协议栈给的SimpleApp例程中,终端入网结果的上层处理有以下代码
void zb_StartConfirm( uint8 status ) {if ( status == ZB_SUCCESS ){myAppState = APP_START;// Set event to bind to a collectorosal_start_timerEx( sapi_TaskID, MY_FIND_COLLECTOR_EVT, myBindRetryDelay ); }else{// Try joining again later with a delayosal_start_timerEx( sapi_TaskID, MY_START_EVT, myStartRetryDelay );} }
我想问这句
osal_start_timerEx( sapi_TaskID, MY_START_EVT, myStartRetryDelay );
有什么用呢,我把他屏蔽后,按键还是一样进行入网流程。
2.入网流程在不定义HOLD_AUTO_START的情况下是自动进行的,假如终端需要长时间不入网,但是需要进行其他动作,比如采集温度之类的,怎么处理才能较好的降低功耗?以下是否合理
UINT16 ZDApp_event_loop( uint8 task_id, UINT16 events ) {uint8 *msg_ptr; ………………if ( events & ZDO_NETWORK_INIT ){ static uint8 joinCount=0;// Initialize apps and start the networkdevState = DEV_INIT;osal_set_event( ZDAppTaskID, ZDO_STATE_CHANGE_EVT ); #ifdef ED_SENSOR if(joinCount++<20) { ZDO_StartDevice( (uint8)ZDO_Config_Node_Descriptor.LogicalType, devStartMode, DEFAULT_BEACON_ORDER, DEFAULT_SUPERFRAME_ORDER ); } else { joinCount=0; MAC_RADIO_RXTX_OFF(); } #else ZDO_StartDevice( (uint8)ZDO_Config_Node_Descriptor.LogicalType, devStartMode, DEFAULT_BEACON_ORDER, DEFAULT_SUPERFRAME_ORDER ); #endif// Return unprocessed eventsreturn (events ^ ZDO_NETWORK_INIT);}
如上,加网20次后关闭加网流程,并关闭RXTX。
我想在不使用RXTX的情况下,关闭32M外部晶振,启用16M内部RC,是否会影响温度采集进程?
VV:
1, 如果else没有进入,那么屏蔽掉代码,肯定不会有影响的
2,可以使用 uint8 ZDApp_StopJoiningCycle( void )停止网络搜索。
3,不建议这么做,Tx/RX/Idle的切换速度很快,上次做操作,不太合适。
David Wang5:
回复 VV:
1.明白,问题解决!
2.使用此函数也是需要判断他扫描了多少次,然后再调用比较合理
3.TX/RX /Idle的切换速度很快?我没明白什么意思,我的终端经常1天甚至3天的时间不在网络,我觉得有必要关闭TX/RX,并将时钟由32MHz XOSC切换到16MHz RC。
整体更改为
if ( events & ZDO_NETWORK_INIT ){static uint8 joinCount=0;// Initialize apps and start the networkdevState = DEV_INIT;osal_set_event( ZDAppTaskID, ZDO_STATE_CHANGE_EVT );#ifdef ED_SENSORif(joinCount++<20){ZDO_StartDevice( (uint8)ZDO_Config_Node_Descriptor.LogicalType, devStartMode,DEFAULT_BEACON_ORDER, DEFAULT_SUPERFRAME_ORDER );}else{uint16 i;\joinCount=0; ZDApp_StopJoiningCycle();//in order to save power,after joining failed,turn off RX,TX and 32MHz XOSC ,turn on 16MHz RCMAC_RADIO_RXTX_OFF();SLEEPCMD &= ~OSC_PD;/* turn on 16MHz RC and 32MHz XOSC */while (!(SLEEPSTA & XOSC_STB) || !(SLEEPSTA & HFRC_STB)); /* wait for 32MHz XOSC and 16MHz RC stable */\asm("NOP");/* chip bug workaround */for (i=0; i<504; i++) asm("NOP");/* Require 63us delay for all revs */CLKCONCMD = (CLKCONCMD_16MHZ | OSC_32KHZ); /* Select 16MHz RC and the source for 32K clock */while (CLKCONSTA != (CLKCONCMD_16MHZ | OSC_32KHZ)); /* Wait for the change to be effective */SLEEPCMD |= OSC_PD;/* turn off 32MHz RC */ClockFlag = RC_16MHZ_ON;IsFirstJoin = FALSE;}#elseZDO_StartDevice( (uint8)ZDO_Config_Node_Descriptor.LogicalType, devStartMode,DEFAULT_BEACON_ORDER, DEFAULT_SUPERFRAME_ORDER );#endif// Return unprocessed eventsreturn (events ^ ZDO_NETWORK_INIT);}
VV:
回复 David Wang5:
如果长时间Tx和RX不会工作的情况下,那么运行在RC 16MHZ也是可以的。
但是要确保收发数据的时候32M的OSC是稳定的