z-stack3.0协议栈开发指导手册中涉及安全设置的10.3.1.3章节中有如下一段话:
It is important to note that legacy devices(implementing R20 or before) will not be able to perform the TCLK exchange process, so if this policy is set to TRUE, legacy devices will not be able to join this network 。
请教一下怎么理解“ legacy devices”这个描述?
user4958201:
指的是R20以前的协议栈版本的设备吗?
Alvin Chen:
回复 Alvin Chen:
You must allow legacy devices to join your Zigbee 3.0 network, they are being rejected because of the new Zigbee 3.0 security scheme. You can allow legacy devices to join by setting BDB_DEFAULT_TC_REQUIRE_KEY_EXCHANGE to FALSE in bdb_interface.h
YiKai Chen:
回复 user4958201:
可以參考 e2e.ti.com/…/674052
user4958201:
回复 Alvin Chen:
您好,想追问一个问题,在节点入网的过程中,节点请求link key,被ZC(trust center)leave了,我是否有办法获知被leave的具体原因?(相同的软硬件,网络节点加到奖金四十个就发生了被leave的情况,一个也加不进去了,即使偶尔加进去了运行也不正常,可能还会掉线,没有之前首次就加入网的运行稳定)
Alvin Chen:
回复 user4958201:
有可能是关联表满了
YiKai Chen:
回复 user4958201:
這樣聽起來像是association table 滿了,這部份應該可以看beacon frame的router/device capacity 來確認
user4958201:
回复 YiKai Chen:
您好1. 协调器的关联表大小设置NWK_MAX_DEVICE_LIST=10,40个节点中有8个ZR设备,ZR设备是没有关联表的吧?整个网络容量是否还有其它限制的参数?2. ZC回复beacon帧中Router capacity 和End device capacity均为TRUE;
user4958201:
回复 Alvin Chen:
请参阅我给YiKai Chen的答复,谢谢了
YiKai Chen:
回复 user4958201:
1.ZR设备也有关联表,整个网络容量沒有其它限制的参数