LaunchPad 13×2 Z-tool "no devices found"

求助:

我想使用 LAUNCHXL-CC1352R1 来尝试 Zigbee-Linux-Gateway.

我想先使 ZNP 功能正常,下载了  Zigbee_3_0_Linux_Gateway_1_0_1.run

解压缩后,将 Zigbee_3_0_Linux_Gateway_1_0_1\Firmware\znp\CC1352R1LP_GW_ZNP_UART.hex 烧录进板子

然后运行 Z-tool ,显示 "no devices found"

我用CCS V9,编译工程 D:\ti\simplelink_cc13x2_26x2_sdk_3_30_00_03\examples\rtos\CC1352R1_LAUNCHXL\zstack\znp,烧录后也是“no devices found”

是不是我哪里理解错了?谢谢! 

Viki Shi:

Therefore the default configuration is 115200 baud with no flow or parity, one stop bit, and 8 data bits. You can test the MT setup by opening Z-Tool and connecting to the device’s enumerated Application/UART COM Port by going to Tools → Settings → Serial Devices, double-clicking on the correct COM Port Name, and modifying the Port Settings as described above.
根据上面设置,另外把handshake改为“RTS/CTS”

YiKai Chen:

參考一下我在 e2e.ti.com/…/3176666 的回覆

gaoyang9992006:

这个问题解决了没?

user6172033:

回复 Viki Shi:

非常感谢!

Z-tool 缺省波特率确实不正确,我改过来了,改成了115200。

另外,流控缺省是 none ,LaunchPad 板子上应该也是None,但是我还是改成RTS/CTS试了一下,还是不行。

Launchpad 上需要进行什么设置吗?或者我有什么办法能确认LaunchPad的软件已经在正常工作了?谢谢!

user6172033:

回复 gaoyang9992006:

还没解决,你有其它建议吗?谢谢!

user6172033:

回复 YiKai Chen:

谢谢!按您 说的这个 CC135CR 版本是 版本C,那应该不能直接使用预编译的 HEX文件 。
我使用 CCS 导入这个项目:
D:\ti\simplelink_cc13x2_26x2_sdk_3_30_00_03\examples\rtos\CC1352R1_LAUNCHXL\zstack\znp\tirtos\ccs
编译、烧录,运行后,Z-TOOL也不能发现这个设备。需要对什么地方的配置进行修改吗?谢谢!

YiKai Chen:

回复 user6172033:

simplelink_cc13x2_26x2_sdk_3_30_00_03也是只能用在rev.E芯片

Viki Shi:

回复 YiKai Chen:

C版本的芯片建议选择sdk 2.30进行测试
Please note that this version of the SimpleLink CC13x2 and CC26x2 SDK is validated with Rev. E devices only. For Rev C or earlier please use v2.30.00.xx of the SimpleLink CC13x2 or SimpleLink CC26x2 SDK.

user6172033:

回复 Viki Shi:

根据 YK Chen 的意见,我手里这两块LAUNCHXL-CC1352R1 都不能支持 新的ZNP,能否更换新的Rev.E 芯片的板子?谢谢!