TI中文支持网
TI专业的中文技术问题搜集分享网站

DLP4500与灰点相机问题

在按照TI提供的dlpu019a.pdf 进行学习时,我使用的是灰点相机 具体型号为CMLN-13S2M-CS

看了接口手册后  确定连线应该没错 大概示意图如下

启动应用后,出现以下错误

Connecting to projector…
Configuring projector…
Connecting to camera…
Configuring camera…
Camera setup FAILED!
ERRORS: 2 and WARNINGS: 0
ERROR: PG_FLYCAP_C_SET_FORMAT_7_FAILED
ERROR: CAMERA_NOT_SETUP

Please resolve the camera connection issue before proceeding to next step…

Texas Instruments DLP Commandline 3D Scanner

0: Exit
1: Generate camera calibration board and enter feature measurements
2: Prepare DLP LightCrafter 4500 (once per projector)
3: Prepare system for calibration and scanning
4: Calibrate camera
5: Calibrate system
6: Perform scan (vertical patterns only)
7: Perform scan (horizontal patterns only)
8: Perform scan (vertical and horizontal patterns)
9: Reconnect camera and projector

Select menu item:

请问会是什么原因 换了几根触发线还是不行?

Kevin Shi:

您好!

感谢您使用TI的DLP产品。

这个问题是应该是camera没有正确工作的原因。请问是否连接了USB线。同时请先确保camera可以正常工作,使用PG的SDK打开camera看是否可以正常拍摄。

user5291297:

回复 Kevin Shi:

确认了相机和投影仪都是正常工作的

Kevin Shi:

回复 user5291297:

您好!
这个问题的出现可能是因为Format 7的验证不正确,这个应该是由于相机不同的原因造成的,其他客户也有遇到这个问题。
请参考
e2e.ti.com/…/551908
可能的原因是TI的参考设计使用的是USB3.0的接口,而您使用的是USB2.0.

请问您是否有其他相机或者可以尝试使用OpenCV的配置。

user5291297:

回复 Kevin Shi:

感谢您的回答目前只有这个相机可以使用尝试使用opencv的配置后却出现以下的问题
Connecting to projector…
Configuring projector…
Connecting to camera…
Connecting to camera FAILED!
ERRORS: 1 and WARNINGS: 0
ERROR: CAMERA_ID_INVALID

Kevin Shi:

回复 user5291297:

您好!
非常遗憾您碰到这个问题,如果OpenCV的配置也不行的话可以能需要更换相机。
或者自己修改代码中API的设置。

赞(0)
未经允许不得转载:TI中文支持网 » DLP4500与灰点相机问题