因为TIDM-02003文档上已经写明了测量上限是12000L/小时,我们有个应用的要求达到16L/秒(换算一下就是57600L/小时),请问还可以使用这套方案吗?目前项目处于方案选型阶段,非常感谢!
Susan Yang:
参考产品主页的说明
Ability to measure a maximum flow rate of 8800 liters/hour (40 gallons/minute) on 25‑mm diameter pipe
Ability to detect a minimum flow rate of <1 liter/hour (0.005 gallons/minute)
Ability to measure a flow rate >25000 liters/hour
Ability to detect a minimum flow rate of <3 liters/hour
您可以配上您的更详细信息,我去咨询一下相关的BU
user6247553:
回复 Susan Yang:
非常感谢!我们的管道内径25mm,在12000L/小时以上直到57600L/小时的流量下,测量精度还可以做到1%吗?谢谢了!
Susan Yang:
回复 user6247553:
这个我需要去和美国工程师确认一下。由于那边是圣诞假期,所以可能会有一些延迟。我会在得到回复后给您消息,谢谢
Susan Yang:
回复 user6247553:
抱歉,由于美国的圣诞假期,回复有些晚了
以下是美国工程师的回复
It is possible to measure 57600LPH on a 25mm diameter pipe. However, the placement of the transducer will also affect the maximum & minimum flow rate. So the question will be what is the minimum flow rate the customer want with a meter with 57600LPH on a 25mm diameter pipe. Usually, with a higher max flow rate the min flow rate goes higher too.