DCA1000EVM: Unable to read FPGA Version. [error -5]

Part Number:DCA1000EVM

目前我是使用AWR 2243 BOOST 以及 DCA 1000 EVM
mmwave studio 版本是3.0.0.14DCA 1000 EVM 剛買不久MATLAB Runtime(v8.5.1, 32-bit)筆電為win 11電源供應器 5V 2A目前的output 是 Unable to read FPGA Version. [error -5]目前已經試過1.關防火牆2.網路線RJ45也是直接連接在儀器上沒有使用轉接口3.另外一臺筆電也是相同情況想詢問如何解決 謝謝

"I am currently using the AWR 2243 BOOST and DCA 1000 EVM.

The mmWave Studio version is 3.0.0.14.

The DCA 1000 EVM was recently purchased.

MATLAB Runtime (v8.5.1, 32-bit).

The laptop runs Windows 11.

The power supply is 5V 2A.

The current output is 'Unable to read FPGA Version. [error -5]'.

I have already tried the following:

  1. Disabling the firewall.
  2. Using a direct RJ45 connection without any adapters.
  3. Trying with another laptop, which shows the same issue.

I would like to inquire about how to resolve this issue. Thank you."

Chris Meng:

你好,

电脑的杀毒软件是否有关闭后尝试?

电脑的IP地址是否配置正常?

更多信息请参考:(+) DCA1000EVM使用指南 – 嵌入式处理 – 技术文章 – E2ETm 设计支持 (ti.com)

Thanks,

Chris

,

CHEN LIANG YU:

是的 防毒皆已關閉,IP位置配置也是正確的

,

CHEN LIANG YU:

,

Chris Meng:

你好,

连接有线时,请关闭无线,再尝试。

Thanks,

Chris

,

CHEN LIANG YU:

已解決 謝謝