IWRL6432BOOST: Demo无法运行

Part Number:IWRL6432BOOSTOther Parts Discussed in Thread:IWRL6432

1.按照指导书,烧录"..\MMWAVE_L_SDK_05_04_00_01\examples\mmw_demo\motion_and_presence_detection\prebuilt_binaries\xwrL64xx\motion_and_presence_detection_demo.release.appimage"配置文件,显示烧录成功

2.将雷达开关调为Function模式(S1开关为[1 0 0 0 1 1 ]; S4开关为[0 0 1 0]),并运行“..\radar_toolbox_2_20_00_05\tools\visualizers\Applications_Visualizer\Industrial_Visualizer\Industrial_Visualizer.exe”可执行文件

3.命令行窗口中自动识别了COM口,GUI上安要求选择设备为"xWRL6432",调整对应的端口号,选择Demo为"x432 Out of Box Demo",点击Connect后,连接成功

4.选择配置文件为“..\radar_toolbox_2_20_00_05\source\ti\examples\People_Tracking\IWRL6432_People_Tracking\chirp_configs\xWRL6432BOOST\Tracking_MidBw.cfg”,开始并发送配置文件后,在命令行窗口中一直显示“ b' ' ”,一段时间后显示“ERROR [gui_parser.py:188] ERROR:No data detected on COM Port, read timed out” "ERROR [gui_parser.py:189] Be sure that the device is in the proper mode, and that the cfg you are sending is valid"

请问这是什么原因导致的,该如何解决?

Rick Lu:

你好,

按照你提供的步骤做是没有问题的。

根据命令行窗口提供的信息,这应该是在串口的问题,程序尝试从串口读取数据时没有检测到任何数据,导致读取操作超时。

你可以尝试更新一下驱动程序,根据

..\radar_toolbox_2_20_00_05\tools\visualizers\Applications_Visualizer\docs\mmWave_Applications_Visualizer_User_Guide.html 检查响应的软件是否已经安装。