TI中文支持网
TI专业的中文技术问题搜集分享网站

TDA4VM: Functional safety ASILD issues

Part Number:TDA4VM

For TDA4VM products, does the MCU domain and hardware integrity meet the requirements of ASIL-D/SIL-3, and does the software characteristics meet them?

Shine:

As per the datasheet, the  TDA4VM device, is Functional Safety-Compliant targeted:

Developed for functional safety applications
Documentation available to aid ISO 26262 functional safety system design up to ASIL-D/ SIL-3 targeted
Systematic capability up to ASIL-D/SIL-3 targeted
Hardware integrity up to ASIL-D/SIL-3 targeted for MCU Domain
Hardware integrity up to ASIL-B/SIL-2 targeted for Main Domain
Safety-related certification 

https://www.ti.com/lit/ds/symlink/tda4vm.pdfFor the software path to functional safety, please reach out to your local TI representative for access to the Safety Manual, and further safety details.