DS90UB953-Q1: ESD issue, Image is stuck

Part Number:DS90UB953-Q1

Hi,  

The MIPI signal will be stuck and then released in ESD contact test(GND, -8KV), this causes the image in infotainment display screen. 

Do we have any special protection method for the signal lines?  The requirement is ESD meets level A under +/-8kV. 

Andy Jin:

Sorry, missed something. 

 this causes the image in infotainment display screen will be stuck and then be OK. 

,

Kailyn Chen:

您好·,明天给您答复。

,

Kailyn Chen:

Hello,

We also have an App Note that discusses ESD protection in our Ser/Des devices, so I recommend looking through this document:

https://www.ti.com/lit/an/slvaf60a/slvaf60a.pdf 

Besides that, here are some general recommendations to improve ESD performance:

Hardware:

Multiple points of grounding
TVS diodes 
Well grounded enclosure

Software:

Increase parity threshold
Optimize AEQ settings
Hold error free frame

Also make sure to follow a structured and repeatable test procedure, in order to minimize variables in the ESD test.

For example, the Ferrite Beads in the UB953 datasheet are recommended to be 1.5-kOhms@100MHz, but the Ferrite Beads that were used vary between 331-Ohms@100MHz and 470-Ohms@100MHz.