DS80PCI102SQ – defect is occurred in X-ray image.

Dear Sir/Madam, 

We found the defect in the X-ray images. May i know

1.cause of defect

2. Does such defect affect the function

Thank you for your help.

Best regards, 

Annie Liu:

抱歉,由于英文论坛维护中,产品工程师暂时无法回复。预计将在下周给您回复

,

Annie Liu:

Please confirm if you have already used this in your design and you are seeing a functionality issue. Also, can you please confirm a working device shows the same x-ray?

,

Venus Yeung:

Not used yet, we just find the defect from the X-ray image

The below photo is from the good part.

We would to know

1.cause of defect

2. Does such defect affect the function

,

Annie Liu:

Suggestion is to first use this part on a test board or evaluation board. This may not affect functional since this seems to be more on the molding compound used versus actual bond wire. Once this is done, please let us know and if needed we can take the next step.