Part Number:PCM3168A
你好!
PCM3168A配置成TDM8输出, LRCKAD 与 LRCKDA 合并后 和 主控芯片的 LRCK 相连
BCKAD 与 BCKDA 合并后 和 主控芯片的 BCK=12.288M 相连,主控SPI模式,PCM3168为slave ,采样率LRCK:48K MCLK: 12.88M, BCK:12.288M;
addr=42, val=0
addr=43, val=0
addr=44, val=0
addr=45, val=0
addr=46, val=0
addr=47, val=ff
addr=48, val=ff
addr=49, val=ff
addr=4a, val=ff
addr=4b, val=ff
addr=4c, val=ff
addr=4d, val=ff
addr=4e, val=ff
addr=4f, val=ff
addr=50, val=1
addr=51, val=6
addr=52, val=0
addr=53, val=0
addr=54, val=0
addr=55, val=0
addr=56, val=0
addr=57, val=0
addr=58, val=d7
addr=59, val=d7
addr=5a, val=d7
addr=5b, val=d7
addr=5c, val=d7
addr=5d, val=d7
addr=5e, val=d7
—readback—:
addr=c0, val=c0
addr=c1, val=6
addr=c2, val=0
addr=c3, val=0
addr=c4, val=0
addr=c5, val=ff
addr=c6, val=0
addr=c7, val=ff
addr=c8, val=ff
addr=c9, val=ff
addr=ca, val=ff
addr=cb, val=ff
addr=cc, val=ff
addr=cd, val=ff
addr=ce, val=ff
addr=cf, val=ff
addr=d0, val=1
addr=d1, val=6
addr=d2, val=0
addr=d3, val=0
addr=d4, val=0
addr=d5, val=0
addr=d6, val=0
addr=d7, val=0
addr=d8, val=d7
addr=d9, val=d7
addr=da, val=d7
addr=db, val=d7
addr=dc, val=d7
addr=dd, val=d7
addr=de, val=d7
TDM8 slave模式 48K输出正常,采样率96K后,改成单速率、双速率、自动速率输出都不正常,麻烦帮忙看看96K配置哪个地方需要更改,谢谢!
Kailyn Chen:
您好, 96Khz的时候输出不正常,具体表现在哪里?
如果输出有噪声的话,我看数据手册Table 4 对于每个采样率 noise free带宽下面有给出,如果96KHz的话,只能配置为dual rate或auto mode,这时候系统时钟为256fs或384fs。 所以如果改成96Khz采样率的话,方便将系统时钟改为24.576Mhz看有改善吗?
,
liu billy:
系数时钟就是24.576M了,是跟BCLK接在一起的.配置为dua rate或auto mode的时候,ADC的DATA就没波形产生了,配置成single rate的时候,就有噪声
,
liu billy:
系统时钟已经是24.576M了,是跟BCLK接在一起的.配置为dua rate或auto mode的时候,ADC的DATA就没波形产生了,配置成single rate的时候,就有噪声。 方便提供一下96K的配置吗?
,
Kailyn Chen:
抱歉,我这边没有PCM3168A在96Khz下的配置可以参考。
如果您使用的EVM,建议使用EVM GUI帮助进行配置。https://www.ti.com.cn/cn/lit/zip/slac268