TI中文支持网
TI专业的中文技术问题搜集分享网站

BQ25611D: Pin 22 REGN problem

Part Number:BQ25611D

Hi Sir 

We have a quation with BQ25611 PIN22 (REGN)
We added a 4.7uF capacitor to REGN. Will the residual charge of this capacitor cause the BQ25611 to reset and register to reset when the Vbus power is terminated?
Please reference as below the photo

Thanks .

Best Regards!!

Star Xu:

您好,数据手册推荐REGN接4.7-μF接地。register reset可以WD_RST,详细请参考数据手册9.4.1 Host Mode and Default Mode

,

Martin Chen:

Hi Sir

目前我們是沒有使用WD_RST的功能我們的問題是

當 VBUS or VBAT pin 掉電又重新上電達到 POR 條件後, 此時如果 REGN pin 上有殘存電壓時, POR(reset) 後 charger 是否還能正常動作?

Sometimes, even when the supply is disconnected ,storage capacitor (REGN 4.7uF)retain some residual voltage, Is this voltage affect the reset of the POR cause the charger ic will not initialize correctly? 

謝謝

,

Star Xu:

您好,POR以后所有参数会恢复dafault值,

Martin Chen 说:當 VBUS or VBAT pin 掉電又重新上電達到 POR 條件後, 此時如果 REGN pin 上有殘存電壓時, POR(reset) 後 charger 是否還能正常動作?

建议您实际操作一下,看是否能正常运作。

,

Martin Chen:

Hi Sir

我們在確認,REGN pin 的殘留電壓,是不是與VBUS or VBAT 沒有直接關係?假設 REGN pin 的殘留電 也不會去影響POR 初始值?

下圖是我們實際量測的波形

Thanks

,

Star Xu:

您好,正在查询,稍后回复。

,

Star Xu:

您好,No related issue has been reported so far.

赞(0)
未经允许不得转载:TI中文支持网 » BQ25611D: Pin 22 REGN problem
分享到: 更多 (0)