TI中文支持网
TI专业的中文技术问题搜集分享网站

TPS65987D: 能否在CC信号不断开重连的情况下进行PDO的协商

Part Number:TPS65987D

现在我使用TPS65987D做与显示器PDO协商

在使用 IIC 写 TPS65987D 的 0x33寄存器设置PDO的时候,需要断开CC信号重连,显示器那边才会重新协商到我设置的值,有没有什么办法不断开CC信号重而让他们重新协商输出到我设置的VBUS

Amy Luo:

您好,

感谢您对TI产品的关注!为更加有效地解决您的问题,我将您的问题发布在了E2E英文论坛上,将由资深的英文论坛工程师为您提供帮助,收到回复后,若有疑问您可以跟进英文工程师的回复:

https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/1119097/tps65987d-can-pdo-be-negotiated-without-the-cc-signal-being-repeatedly-opened-and-reconnected

,

Amy Luo:

E2E英文论坛工程师已回复:

After the 0x33 Sink Capabilities register has been updated, the customer can use the 'GSrC' 4CC command to force the connected device to re-send its source capabilities and renegotiate a new PD contract with the updated Sink Capabilities.

The flow would be as follows:

1. Updated Sink Capabilities in 0x332. Send 'GSrC' 4CC Command3. New PD contract will be negotiated

赞(0)
未经允许不得转载:TI中文支持网 » TPS65987D: 能否在CC信号不断开重连的情况下进行PDO的协商
分享到: 更多 (0)