Other Parts Discussed in Thread:TMS320C5535
我使用的是CCS5.2版本,用的TMS320C5535,SEED-XDS510PLUS仿真器驱动安装了,但是连接上SEED-XDS510PLUS仿真器时,进行Test connection时,出现了以下错误:
The controller has a version number of '1' (0x00000001).
The controller has an insertion length of '16' (0x00000010).
This utility will attempt to reset the controller.
A error occurred while attempting to reset the controller.
—–[An error has occurred and this utility has aborted]——————–
This error is generated by TI's USCIF driver or utilities.
The value is '-342' (0xfffffeaa).
The title is 'SC_ERR_HUNG_COMMAND'.
The explanation is:
Failure due to the controller command-finish taking too long.
[End]
Nancy Wang:
请问是自制板吗?请先确实一下com口能正常识别的吗?
,
user6441590:
是自制板,端口可以正常识别
,
Nancy Wang:
换一个仿真器试一下看看,做一些交叉实验。
另外电源,复位以及jtag部分信号都检查看一下有没有问题,也不排除硬件问题导致的。
,
user6441590:
在进行Test connection时,还会出现上面的错误,但是可以debug,在线仿真,跑程序