F28016 Held in Reset?

与目标板连接时,出现以下错误,EMU0和1都上拉,TRST下拉信号为高,TCK时钟12.5M  dsp复位引脚高电平,时钟信号20MHz,XCLKOUT为2.5MHz

Error connecting to the target:
Error 0x00000024/-1137
Error during: Register, Execution,
It appears that the target is being held in reset.  This may be
due to Wait-In-Reset (WIR) configuration set by the EMU0=0
and EMU1=1 pin settings.  If this is the case, DISCONNECT
all CONNECTED devices including icepick and then select
RETRY to clear the WIR configuration.

If this is a multi-core system, the master CPU may not be
releasing the DSP/MCU from reset.  Please check your
configuration in CC_setup and/or your GEL file to ensure that
nothing is blocking the DSP/MCU from being released from reset

I/O Port = 510

Board Name: F2808 XDS510USB Emulator
Cpu Name: cpu_0

Abort:                Close Code Composer Studio.
Retry:                Try to connect to the target again.
Cancel:                Remain disconnected from the target
Diagnostic:        Run diagnostic utility.

按了Disconnect后出现

Terry Deng:

外部晶振请使用10M

与目标板连接时,出现以下错误,EMU0和1都上拉,TRST下拉信号为高,TCK时钟12.5M  dsp复位引脚高电平,时钟信号20MHz,XCLKOUT为2.5MHz

Error connecting to the target:
Error 0x00000024/-1137
Error during: Register, Execution,
It appears that the target is being held in reset.  This may be
due to Wait-In-Reset (WIR) configuration set by the EMU0=0
and EMU1=1 pin settings.  If this is the case, DISCONNECT
all CONNECTED devices including icepick and then select
RETRY to clear the WIR configuration.

If this is a multi-core system, the master CPU may not be
releasing the DSP/MCU from reset.  Please check your
configuration in CC_setup and/or your GEL file to ensure that
nothing is blocking the DSP/MCU from being released from reset

I/O Port = 510

Board Name: F2808 XDS510USB Emulator
Cpu Name: cpu_0

Abort:                Close Code Composer Studio.
Retry:                Try to connect to the target again.
Cancel:                Remain disconnected from the target
Diagnostic:        Run diagnostic utility.

按了Disconnect后出现

Lisa:

回复 Terry Deng:

为什么使用10M的晶振 datasheet上是使用20M晶振,我有一块好的F28016的最小系统也是使用的20M的晶振 能够正常连接上

与目标板连接时,出现以下错误,EMU0和1都上拉,TRST下拉信号为高,TCK时钟12.5M  dsp复位引脚高电平,时钟信号20MHz,XCLKOUT为2.5MHz

Error connecting to the target:
Error 0x00000024/-1137
Error during: Register, Execution,
It appears that the target is being held in reset.  This may be
due to Wait-In-Reset (WIR) configuration set by the EMU0=0
and EMU1=1 pin settings.  If this is the case, DISCONNECT
all CONNECTED devices including icepick and then select
RETRY to clear the WIR configuration.

If this is a multi-core system, the master CPU may not be
releasing the DSP/MCU from reset.  Please check your
configuration in CC_setup and/or your GEL file to ensure that
nothing is blocking the DSP/MCU from being released from reset

I/O Port = 510

Board Name: F2808 XDS510USB Emulator
Cpu Name: cpu_0

Abort:                Close Code Composer Studio.
Retry:                Try to connect to the target again.
Cancel:                Remain disconnected from the target
Diagnostic:        Run diagnostic utility.

按了Disconnect后出现

Terry Deng:

回复 Lisa:

这个和仿真器有关,我曾经见过有些仿真器用10M外部时钟才能用,你可以试试

赞(0)
未经允许不得转载:TI中文支持网 » F28016 Held in Reset?
分享到: 更多 (0)