TI中文支持网
TI专业的中文技术问题搜集分享网站

IWR6843: 通过XDS110连接CCS不稳定问题

Part Number:IWR6843

您好!

早上的时候一直可以通过XDS110连接到CCS上,并可以加载程序,进行后面的操作,中午单板断电了,下午重新上电后就一直连接不上CCS了。环境没有变化,单板设置也没有变化,报错如下:

以前也出现过这样的错误,一般都是通过重新上下电,或者插拔串口线,但是今天反复试了很多次了,都不行。

[Start: Texas Instruments XDS110 USB Debug Probe_0]

Execute the command:

%ccs_base%/common/uscif/dbgjtag -f %boarddatafile% -rv -o -S integrity

[Result]

—–[Print the board config pathname(s)]————————————

C:\Users\yutao\AppData\Local\TEXASI~1\CCS\
ccs930\0\0\BrdDat\testBoard.dat

—–[Print the reset-command software log-file]—————————–

This utility has selected a 100- or 510-class product.
This utility will load the adapter 'jioxds110.dll'.
The library build date was 'Nov 25 2019'.
The library build time was '16:55:29'.
The library package version is '8.4.0.00006'.
The library component version is '35.35.0.0'.
The controller does not use a programmable FPGA.
The controller has a version number of '5' (0x00000005).
The controller has an insertion length of '0' (0x00000000).
This utility will attempt to reset the controller.
This utility has successfully reset the controller.

—–[Print the reset-command hardware log-file]—————————–

The scan-path will be reset by toggling the JTAG TRST signal.
The controller is the XDS110 with USB interface.
The link from controller to target is direct (without cable).
The software is configured for XDS110 features.
The controller cannot monitor the value on the EMU[0] pin.
The controller cannot monitor the value on the EMU[1] pin.
The controller cannot control the timing on output pins.
The controller cannot control the timing on input pins.
The scan-path link-delay has been set to exactly '0' (0x0000).

—–[An error has occurred and this utility has aborted]——————–

This error is generated by TI's USCIF driver or utilities.

The value is '-233' (0xffffff17).
The title is 'SC_ERR_PATH_BROKEN'.

The explanation is:
The JTAG IR and DR scan-paths cannot circulate bits, they may be broken.
An attempt to scan the JTAG scan-path has failed.
The target's JTAG scan-path appears to be broken
with a stuck-at-ones or stuck-at-zero fault.

[End: Texas Instruments XDS110 USB Debug Probe_0]

Nancy Wang:

参考以下链接中 invalid data read back 看一下:

dev.ti.com/…/node

赞(0)
未经允许不得转载:TI中文支持网 » IWR6843: 通过XDS110连接CCS不稳定问题
分享到: 更多 (0)