Part Number:IWR6843ISKOther Parts Discussed in Thread:IWR6843, MMWAVEICBOOST
QT version = 5.9.1
QMetaObject::connectSlotsByName: No matching signal for on_buttonBox_accepted()
Serial Port Found
Data Port Number is "COM6"
User Port Number is "COM15"
Data port succesfully Open
User port succesfully Open
Configuration File Name Read from the GUI is %s/n "xwr1642_profile_VitalSigns_20fps_Back.cfg"
QMetaObject::connectSlotsByName: No matching signal for on_buttonBox_accepted()
"COM15"
Configuration File Path is %s/n "C:/ti/mmwave_industrial_toolbox_4_9_0/labs/vital_signs/68xx_vital_signs/gui/profiles/xwr1642_profile_VitalSigns_20fps_Front.cfg"
"sensorStop"
"flushCfg"
"dfeDataOutputMode 1"
"channelCfg 15 3 0"
"adcCfg 2 1"
"adcbufCfg -1 0 0 1 0"
"profileCfg 0 60.25 7 6 57 0 0 65 1 200 4000 0 0 40"
"chirpCfg 0 0 0 0 0 0 0 1"
"frameCfg 0 0 2 0 50 1 0"
"lowPower 0 1"
"guiMonitor 0 0 0 0 1"
"calibDcRangeSig -1 0 0 0 0"
"vitalSignsCfg 0.3 0.9 256 512 4 0.1 0.05 100000 300000"
"motionDetection 1 20 2.0 0"
"sensorStart"
""
"sensorStop"
"flushCfg"
"dfeDataOutputMode 1"
"channelCfg 15 3 0"
"adcCfg 2 1"
"adcbufCfg -1 0 0 1 0"
"profileCfg 0 60.25 7 6 57 0 0 65 1 200 4000 0 0 40"
"chirpCfg 0 0 0 0 0 0 0 1"
"frameCfg 0 0 2 0 50 1 0"
"lowPower 0 1"
"guiMonitor 0 0 0 0 1"
"calibDcRangeSig -1 0 0 0 0"
"vitalSignsCfg 0.3 0.9 256 512 4 0.1 0.05 100000 300000"
0.3
0.9
4
"motionDetection 1 20 2.0 0"
"sensorStart"
""
Chirp Duration in us is : 50
Chirp Bandwidth in kHz is : 3250
Maximum Range in Meters is : 9.23077
Range-FFT size is : 256
Range-Bin size is : 0.0360577
Range-Bin Start Index is : 8
Range-Bin End Index is : 24
Total Payload size from the UART is : 252
Padding Factor is : 8
Total Payload size from the UART is : 256
我想问下是不是我操作有问题,之前资源中心iwr6843的指导的,现在查看没有了
Shine:
资源中心可以点击最新版本旁边的竖的三个点,选择想要显示的版本号。https://dev.ti.com/tirex/explore/node?a=VLyFKFf__4.9.0&node=ALCGDS5qxpkOXRTFNYu87Q__VLyFKFf__4.9.0
可以看一下板子的拨位开关是否拨到function mode 3. Setup the EVM for Functional Modehttps://dev.ti.com/tirex/explore/content/mmwave_industrial_toolbox_4_9_0/labs/common/docs/hardware_setup/hw_setup_mmwaveicboost_mode_functional.html另外,看一下IWR6843硅版本是不是2.0的以及user guide里的sensor placement。
,
? ?:
QMetaObject::connectSlotsByName: No matching signal for on_buttonBox_accepted()没有信号啥原因
,
Shine:
请看一下下面的帖子。https://e2e.ti.com/support/sensors-group/sensors/f/sensors-forum/799522/iwr6843isk-mmwave_industrial_toolbox_3_4_0—lab0026_vital_signs_68xx—qmetaobject-connectslotsbyname-no-matching-signal-for-on_buttonbox_accepted
,
? ?:
没解决
,
? ?:
会不会是电源问题
,
Shine:
请问电源用的是多少?
,
? ?:
我直接用的计算机端口供电
,
Shine:
您的计算端口能提供5v/3A的电压和电流?
,
? ?:
换了5v3a电源适配器,问题依旧
,
Chris Meng:
你好,
你的标题是“我把vital_signs_demo_68xx.bin烧写进isk,然后搭配boost板”。请问你使用的ISK是哪个版本的?ISK和MMWAVEICBOOST上的跳线开关都正确配置了吗?
,
Chris Meng:
你好,
请问你的电脑是win10么?下面的软件有正确安装么?是否有尝试过其他电脑?
vc runtime which can be downloaded here