TI中文支持网
TI专业的中文技术问题搜集分享网站

IWR6843ISK: VitalSignsRadar_Demo gui tool 打开串口失败

Part Number:IWR6843ISKOther Parts Discussed in Thread: MMWAVEICBOOST

问题描述:

使用IWR6843ISK 开发板,下载C:\ti\mmwave_industrial_toolbox_4_10_1\labs\Vital_Signs\68xx_vital_signs\prebuilt_binaries\vital_signs_demo_68xx.bin, 成功下载,切换S1到功能模式,如图。

IWR6843ISK与pc连接,能正常检测到设备:

打开GUI 工具C:\ti\mmwave_industrial_toolbox_4_10_1\labs\Vital_Signs\68xx_vital_signs\gui\gui_exe\VitalSignsRadar_Demo.exe,自动检测Com Port,cmd line显示打开失败:

QT version = 5.9.1
QMetaObject::connectSlotsByName: No matching signal for on_buttonBox_accepted()
Serial Port Found
Data Port Number is "COM7"
User Port Number is "COM7"
Data port succesfully Open
User port did not Open
QIODevice::write (QSerialPort): device not open

上述log可以看到User Port Num和Data Port Num选择的都是COM7,实际应该是COM8,即使手动修改User ComData Port Number 为COM8,点击Refresh,也没有作用,手动点击Settings,进去后也无法输入COMx端口号。请问可能是哪里错了?感谢支持!

Shine:

这个demo还需要MMWAVEICBOOST板子,请看下面user guide的说明。https://dev.ti.com/tirex/explore/node?node=AFHfI9gKQ7lfXf2HcRSFdQ__VLyFKFf__LATEST&r=AocYeEd__3.0.0

Hardware

Item
Details

Device
Industrial mmWave Carrier Board and either one of the following antenna modules

IWR6843ISK Antenna Module OR IWR6843ISK_ODS Antenna Module OR IWR6843AOPEVM.

,

chen sam:

谢谢,大概知道原因了。另外我想问下,如果要脱离MMWAVEICBOOST,单独使用iwr6843isk实现这个demo是否可行,我看到其他的,比如people count是可以脱离MMWAVEICBOOST来使用的

,

Shine:

因为这个GUI仅支持识别XDS110的串口。有的demo GUI不需要,具体要看demo里的hardware要求。