BQ27Z561EVM-011: bqStudio using error in bq27z561EVM-011

Part Number:BQ27Z561EVM-011Other Parts Discussed in Thread: BQSTUDIO

use bq27z561EVM-011 in bqStudio, in Technical Documents of sluuc54b , at the page 99 , the document shows the command example , I follow the example to write the command in 0x40A9, want to change the Manufacture data,When I write the data and read the address data, I find that the data has not been modified.
Attached is the operation record .The original data is 5221, which needs to be modified to 52B1

Star Xu:

您好,advanced COMM I2C修改参数请参考下面链接

e2e.ti.com/…/3192632

,

yuan zhou1:

您好,你发的链接地址不能全部打开,能付上完整的链接吗?

,

Star Xu:

您好,链接如下:

https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/862830/bq27z561-how-to-test-int-functionality/3192632#3192632

,

yuan zhou1:

,

yuan zhou1:

无法直接点开链接

,

yuan zhou1:

您好,多谢你的答复,在链接的文档中MAC data block length是怎么计算得到的,多谢!

,

Star Xu:

您好,The length byte for all MAC commands includes the 2-byte command, the 1-byte checksum, the 1-byte length,and 1 to 32 bytes of data

详细请参考TRM 13.1.29 0x61MACDataLength()