Part Number:TPS25750
I want to know why there is a 5V3A sourcing power path?
This requires a DCDC(can bear 3.35A) from battery to PP5V.
Why not merge the 5V3A sourcing power rail and PPHV sourcing/sink power path?
Amy Luo:
您好,
TPS25750可以通过TPS25750 Application Customization Tool将其配置为以下几种工作方式,当TPS25750D用作 UFP (SINK),PP5V 电源不是必需的,可以对地短路