电脑都发现不了驱动,错误log:
[Start: Blackhawk XDS560v2-USB System Trace Emulator_0]
Execute the command:
%ccs_base%/common/uscif/dbgjtag.exe -f %boarddatafile% -rv -o -F inform,logfile=yes -S pathlength -S integrity
[Result]
—–[Print the board config pathname(s)]————————————
C:\Users\uidq1196\AppData\Local\TEXASI~1\
CCS\ccs1000\2\0\BrdDat\testBoard.dat
—–[Print the reset-command software log-file]—————————–
This utility has selected a 560/2xx-class product.
This utility will load the program 'bh560v2u.out'.
E_RPCENV_IO_ERROR(-6) No connection: emulator was not found
Download failed for file D:\software\ti\ccs1000\ccs\ccs_base\common\uscif\xds560v2.out
An error occurred while soft opening the controller.
—–[An error has occurred and this utility has aborted]——————–
This error is generated by TI's USCIF driver or utilities.
The value is '-250' (0xffffff06).
The title is 'SC_ERR_ECOM_EMUNAME'.
The explanation is:
An attempt to access the debug probe via USCIF ECOM has failed.
[End: Blackhawk XDS560v2-USB System Trace Emulator_0]
Susan Yang:
您的电脑的设备管理器中是否可以识别到设备?请给出相关的截图。
若是不能识别或者有黄色感叹号的话,您需要重新安装一下驱动
另外您是在Windows下使用还是Linux?
之前有客户遇到了类似的问题,您可以参考一下
e2e.ti.com/…/220692
Vern:
回复 Susan Yang:
我的电脑没有识别到设备,连黄色叹号都没有。我是win10系统。
我换了别的同事的电脑试过也没有反应
Susan Yang:
回复 Vern:
Vern我的电脑没有识别到设备,连黄色叹号都没有。
就是电脑插入该仿真器后,在设备管理器中没有反应?理论上应该如下所示。
或者您换一下USB连接线试试?
更多信息您可以点击下面的链接
http://dev.ti.com/tirex/explore/node?node=AA-h-TnEUGzufIOGlKT-vA__FUz-xrs__LATEST
Vern:
回复 Susan Yang:
我试过,检测不到的。
Susan Yang:
回复 Vern:
之前这个XDS560可以使用吗?一般直接检测不到的话,是XDS硬件本身有问题
请问您现在要烧录的是什么芯片?
Vern:
回复 Susan Yang:
之前是可以用的,我在调试TDA4x;
Susan Yang:
回复 Vern:
之前是可以使用的话,后面是对它做了什么操作呢?
另外TDA4x的话,一般是由下面版块的工程师来支持的
e2e.ti.com/…/791
Vern:
回复 Susan Yang:
没做过什么操作。
这个设备还有一个网口,这个是怎么用的,可以通过网口调试吗?
Susan Yang:
回复 Vern:
很抱歉,关于TDA4x,一般是由上面我提到的版块的工程师来支持的而不是C2000论坛
Vern:
回复 Susan Yang:
好的,我去那个板块问问,谢谢!