Using tps54334 switching power supply chip, the chip burn rate in the field is more than 30%

Using tps54334 to reduce 24V to 6V, the load current is relatively small, about 24Ma.

After four months of operation, the chips were burned down, with a rate of 30%.

The burning phenomenon is: all the SW pins are short circuited to the ground, even some boot pins or VIN pins are short circuited to the ground, and some PGOOD pins are short circuited to the ground.

The accessories are schematic diagram, PCB diagram and SW oscilloscope signal.

Marvellous Liu:

首先从SW引脚来看你的电压早就超过了芯片最大允许电压;这是个风险点。

user5322468:

回复 Marvellous Liu:

 主要超过的是低电平,负5.7V,时间段很短只有20NS左右。如图

Johnsin Tao:

回复 Marvellous Liu:

Hi系统面看看一下输入电压上是否有过冲?

user5322468:

回复 Johnsin Tao:

输入电压24v,无过冲

Marvellous Liu:

回复 user5322468:

轻载下过冲高,下冲也很低是正常的;但是DCDC测试一般是选20MHz带宽测试,再测试一下看看;

user5322468:

回复 Marvellous Liu:

带宽限制

Marvellous Liu:

回复 user5322468:

这个波形看着很标准啊,应该没啥问题啊!

Marvellous Liu:

回复 user5322468:

你可以做个试验,在输出端加电源,在输入端及SW引脚测量波形看看;

user5322468:

回复 Marvellous Liu:

这个测试的目的是什么?

Marvellous Liu:

回复 user5322468:

市场上很多DCDC存在Buck变换器反向电流未处理检测的问题,就导致输出到输入进行BOOST作用,使得输入和SW引脚损坏。