如题
bing xu5:
还有FullChargeCapacityTrue
Star Xu:
Full Charge Capacity (FCC) and Remaining Capacity (RM) are both compensated values which depend on the rate, temperature, and impedance of the battery. This is different from Full Available Capacity (FAC) and NomAvailCap (NAC) which assume nominal temperature and a very light load. If at rest, FCC and RM will usually be calculated by the gauge by running a simulation at the current temperature assuming a load equivalent to Avg I/P Last Run (in dataflash).
实际电量参考FCC
bing xu5:
回复 Star Xu:
你好
1、上面这段英文是自己写的还是摘自哪篇文档?如果是文档,帮忙把这篇文档分享下谢谢!
2、FCC 与FCC True ,RM 与RM True啥关系?
3、我给G27510施加800mA的电流负载,流量计显示的是890mA,是不是校准出现了问题?
Sammi Shang:
回复 bing xu5:
2. FCC true和RM true可根据真实的电流充放电积分进行计算,计算方法在如下链接中:https://e2e.ti.com/blogs_/b/fullycharged/archive/2016/11/04/how-accurate-is-your-battery-fuel-gauge-part-2-2。
3. 是校准出现了问题,需要校准成功之后才可进行其他操作。
Star Xu:
回复 bing xu5:
这段英文没有文档
bing xu5:
回复 Star Xu:
27510G3充电显示100%跟亮绿灯间隔时间很长,最短的也有半个多小时,长的能达一个多小时,这个跟什么因素有关?如何缩短?充电芯片的截止电流为78mA,目前设置Taper Current 为100mA
Star Xu:
回复 bing xu5:
建议您将充电芯片的截止电流设为一致。
现在的问题是充电芯片一值在充电,但是gauge判断电池已经充饱。
bing xu5:
回复 Star Xu:
不好意思,没明白!是说Taper Current 电流设置跟截止电流一致吗?还有Gauge是根据哪几个参数判断电池已经充饱的?麻烦描述详细一些,谢谢!
bing xu5:
回复 bing xu5:
更直白一点就是调整哪些参数可以缩短流量计显示100%跟充电芯片亮绿灯的时间间隔