BQ78350 EDV2 EDV1 EDV0 如何配置?
Star Xu:
The EDV2 threshold is set to the 7% SOC voltage, EDV1 is set to the 3% SOC voltage and EDV0 is set to the 0% SOC voltage. If you are using EDV mode, then these thresholds must be found by analyzing discharge data to determine the value of the parameters to enter into the data flash. If you are using CEDV mode, then the gauge will calculate these thresholds based on the CEDV Coefficients and these must be calculated using the online GPCCEDV tool. The mode is selected with the CEDV bit in the CEDV Config register.
BMS:
回复 Star Xu:
EDV 不使用有没有大问题?
Star Xu:
回复 BMS:
可以用CEDV mode
BMS:
回复 Star Xu:
那我把 EDV_CMP标志位关闭! CEDV mode 是开启那个标志位?