EMB1428主动均衡控制

目前正在使用EMB1428+1499做锂电池的主动均衡,在调试过程中出现SPI控制命令下发后回复错误码0X1011,每次都是回复这个错误,没有出现Fault中断,使用示波器查看CEXT1和CEXT2波形,有方波,但是幅值为7V

Star Xu:

Fault 1011 is an indication of bg_good going low (table 3 of the data sheet) unexpectedly. From figure 4 you can see the dependencies are VDDCP, the Cpgood signal, 12V or internal reference damaged. You might check for a missing or high impedance power pin connection, or open or short which keeps the charge pump from operating properly.If it shows up when only certain switches are selected perhaps it could be a short on those gate drivers. If the board circuit is correct, and well connected, it may be a damaged part.

user1969660:

回复 Star Xu:

检查图4中影响bg_good的几个因素,12V正常,VDDCP电压不足,charge pump应该没有正确工作,因为我发现CEXT1和CEXT2的电压不足(幅值只有7V,频率为1MHz)。今天尝试将EMB1499去掉,开始时Fault[] = 0x1000,将EN取反后接到DONE,然后Fault[] = 0x1110,还没有处理DIR引脚,但是在这个过程中没有测试到CEXT1和CEXT2 的方波电压。

user1969660:

回复 user1969660:

EMB1428主动均衡控制问题分析.docx

sun loyun:

回复 user1969660:

您好,我目前也在使用emb1428做主动均衡控制,我也遇到了charge pump没有工作CEXT1和CEXT2没有方波出现,电压也不足,但我的Fault回传值是正确的0xa1,想知道您是怎么处理这个问题,还有DIR这个引脚要怎么接,因为我是只有单用emb1428,谢谢。

user1969660:

回复 sun loyun:

我的是因为二极管封装画反了导致的