TI中文支持网
TI专业的中文技术问题搜集分享网站

bq40z50 r1 均衡时电流显示

各TI达人们,好!

有个问题请教下:当开启CB均衡时,充电时在满足均衡条件时开启均衡,在断开充电后,一段时间内CB仍置位,且各cell current显示均衡电流,那怎么也在Current、Average Current那也显示有电流呢?照理说应显示0值才对吧,毕竟这个均衡电流是没有经过sense电阻的啊

Star Xu:

您看一下CBR有没有set,[CBR] bit can enable cell balancing in REST. Also, it is good to note that occasionally the gauge will need to measure the OCV to update the DOD, and cell balancing may be paused for ~30 minutes to allow the cells to reach a REST state to take this measurement when you are have [CBR] enabled.

user1943562:

回复 Star Xu:

CBR=0,主要的问题是:均衡时,Current、Average Current怎么会显示电流?

Star Xu:

回复 user1943562:

AVERAGE CURRENT是一分钟的平均电流。所以拔掉充电器,AVERAGE CURRENT也不是马上变为0

user1943562:

回复 Star Xu:

在充电停止后,最大电芯压差大于10mV,CB=1好几个小时(CBR=0),相应的current及Average current也一直有小电流14左右(设置deadband=8)

DateTime
Voltage
Current
AvgCurr
CellVolt1
CellVolt2
CellVolt3
CellVolt4
vBAT
vPACK
CellCurr1
CellCurr2
CellCurr3
CellCurr4

2019/8/15 9:14
16803
14
73
4212
4214
4168
4205
16782
16783
16
6
12
7

2019/8/15 13:11
16583
14
14
4178
4145
4137
4129
16567
16570
9
17
15
10