一、 外观检验(Appearance Inspection):
The appearance shall be free from deformation,oxidation,contamination,crack and
mark as required.
二、 功能测试(Function Test):
2.1测试环境 Test Environment
Temperature and Humidity:24.4℃/50.5%RH
Test Equipment:
Fluke 289C True RMS Multimeter
Test Method:
- Check the Default PGA970EVM Jumper Configuration was Normal:
Jumpers |
Options |
Jumpers |
Options |
|
|
|
|
J16 |
Open |
J2 |
1 and 2 |
|
|
|
|
J17 |
Open |
J7 |
1 and 2 |
|
|
|
|
J18 |
Closed |
J11 |
Closed |
|
|
|
|
J1 |
Closed |
J12 |
Closed |
|
|
|
|
J4 |
Closed |
J19 |
Closed |
|
|
|
|
J6 |
Closed |
J9 |
Closed |
|
|
|
|
- Power ON The Multimeter and turn it to “Ω” Options
- Check the resistance like below:
Item |
Normal Range |
Test Value |
|
|
|
Vdd and Gnd(TP21,TP24) |
>100 ohm |
27.7 ohm |
|
|
|
C13 |
>100 ohm |
25 ohm |
|
|
|
Q3,2-4 and 3 |
Normal open |
7.8 ohm |
|
|
|
|
Table:1 |
|
Pass Condition: The Normal resistance should be Like the table 1.
2.2 Test Capture:
Test Picture
VDD and Gnd(Left)
Q3 Drain and Source
GND(Right)
三、 检验结果(Test Result):
After confirmation, the power supply of the product is abnormal and the
test result Fails.
四、 参考资料(Reference Data)
l The PGA970EVM schematics:
Kailyn Chen:
您好,您的附图我这边都没有显示出来。
根据您的描述,就是发现EVM板的功能性测试不正常是吗? 您是在哪里订购的?
user5958013:
回复 Kailyn Chen:
电源不正常,总是失败的